<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-15 21-51-48
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 61 dBuV VOLTAGE
Pilot RDS Phase Difference
6.6 kHz 4.3 kHz -11 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
14 kHz 71 kHz 4398 61,4598
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,6 dBr 7,66 dBr 8,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 21:51, 15.09.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (61 dBuV) Max at: 71 kHz MIN: 14 kHz % above 75 kHz: 61,4598 Acquired: 2025/09/15 21:50:44 Total samples: 4398 Equivalent time: 0:03:39 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 8,2 dBr MIN: 6,6 dBr AVE: 7,66 dBr % above 10,2 dBr: 0,0 Last value: 7,5 dBr (2025/09/15 21:50:43) Station: 96.90 MHz, signal: 4/5 (61 dBuV) 21:44 21:45 21:46 21:47 21:48 21:49 21:50 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality